Auto Hematology Analyzer F-HMA101
Throughput | 60 Samples/Hour |
Sample Volume | 10 μL |
Prediluted Mode | 20 μL |
Storage | Up to 60000 results |
Principles | Impedance method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Tri-angle laser scatter method for WBC 5-part differential analysis and WBC counting |
Parameters | 27 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym# ,Mon#, Neu#, Eos# , Bas#, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-CV, RDW-SD, PLI, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY# 3 histograms for WBC, RBC and PLT 3 DIFF scatter grams and 1 BASO scatter gram |
Reagent | DIL-C Diluent, LYC-1 LYSE, LYC-2 LYSE, CLE-P |
Linearity Range | WBC (0.00-300.00)X 10%/L RBC (0.00-8.50)X1012/L HGB (0-250)G/L PLT (0-3000)X 10%/L HCT 0.0-67.0% |
Display | 2.8-inches color LCD |
Working Mode | one-step/ slow/ fast testing mode |
Test Items | GLU, BIL, SG, KET, BLD, PRO, URO, NIT, LEU, VC and PH |
Test Speed | 120 tests/ hour or 60 tests/hour |
Channels | Dual channel |
Test Method | Double magnetic route |
Test Report Parameters | PT (prothrombin time) APTT (partial thromboplastin time) TT (thrombin time) Fbg (fibrinogen) |
Coagulation Factors | Exogenous, endogenous) are expressed in terms of ratio, activation (A%) and international normalized ratio (INR). |
Test Channels | 4 channels; 4 different parameter analysis at the same time. |
Reagent Consumption | less than 20 uL, open reagent |
Preheating Position Sample | 24 positions |
Regent Preheat Position | 6 positions |
Biochemistry Analyzer F-BCA101
Tests / hour | 300 Tests/Hour |
Light Source | Halogen Lamp |
Wavelength | 340 nm, 405 nm, 450 nm, 510 nm, 546 nm, 578 nm, 630 nm, 670 nm |
Reagent and Sample Tray | 60 Sample and 60 Reagent |
Dry Biochemistry Analyzer F-BCA102
Data Input Display | 4.3 inch touch screen |
Mode of Operation | Continuous |
Ambient Temperature | 10 to 30 ℃(50 to 86 ºF), indoor use |
Humidity | 40% to 85% |
Soxhlet Extractor Fat Analyzer F-SFA101
Temperature range | Room temperature +5 ℃to 300 ℃ |
Measuring Range | 0.1 to 100% |
Temperature accuracy | ±1℃ |
Reproducibility | Relative error 1% |
Soxhlet Extractor Fat Analyzer F-SFA102
Temperature range | Room temperature +5 ℃ to 280 ℃ |
Measuring Range | 0.1 to 100% |
Temperature accuracy | ±1℃ |
Sample weight | 0.5 to 15 g(generally 2 to 5 g depending on sample) |
Measuring Range | 0.1% to 100% |
Sample Weight | 0.5 g to 3 g |
Repeatability Error | Craw Fiber Content below 10%, ≤0.4% | Craw Fiber Content above 10%, ≤1% |
Capacity | 6 pcs/batch |
Measurement Range | 0-10000 mg/l |
Detection Limit | 5 μg/l (ppb) |
Digestion Mode | Wet chemical Oxidation by UV |
Detector | NDIR |
Measurement Range | 0-30000 mg/l |
Detection Limit | 50 μg/l (ppb) |
Digestion Mode | High Temperature Combustion |
Detector | NDIR |
Type | Offline |
Measurement range | 0.001 to 1.5 mg/L (ppm) |
Detection limit | 1 ppb |
Maximum tolerance | ± 5% |
Type | Online |
Measurement range | 0.001 to 1.5 mg/L (ppm) |
Detection limit | 1 ppb |
Maximum tolerance | ± 5% |
Halogen Moisture Analyzer F-HMOA101
Range | 10 mg to 110 g |
Readability | 10 mg |
Temperature range | 40 to 199°C |
Heat source | Halogen lamp-1 |
Halogen Moisture Analyzer F-HMOA102
Range | 5 mg to 110 g |
Readability | 5 mg |
Temperature range | 40 to 199°C |
Heat source | Halogen lamp-1 |
Halogen Moisture Analyzer F-HMOA103
Range | 2 mg to 110 g |
Readability | 2 mg |
Temperature range | 40 to 199°C |
Heat source | Halogen lamp-1 |
Halogen Moisture Analyzer F-HMOA104
Range | 1mg to 110 g |
Readability | 1 mg |
Temperature range | 40 to 199°C |
Heat source | Halogen lamp-2 |
Halogen Moisture Analyzer F-HMOA105
Range | 1 mg to 110 g |
Readability | 1 mg |
Temperature range | 40 to 199°C |
Heat source | Halogen lamp-2 |
Halogen Moisture Analyzer F-HMOA201
Range | 4 mg to 110 g |
Readability | 1 mg |
Temperature range | 40 to 230 °C |
Communication mode | Cable |
Halogen Moisture Analyzer F-HMOA202
Range | 4 mg to 110 g |
Readability | 1 mg |
Temperature range | 40 to 230 °C |
Communication mode | Wireless |
Halogen Moisture Analyzer F-HMOA203
Range | 4 mg to 210 g |
Readability | 1 mg |
Temperature range | 40 to 230 °C |
Communication mode | Cable |
Halogen Moisture Analyzer F-HMOA204
Range | 4 mg to 210 g |
Readability | 1 mg |
Temperature range | 40 to 230 °C |
Communication mode | Wireless |
Nano Particle Size Analyzer F-NPSA101
Measuring range | 1 nm-10000 nm |
Concentration range | 0.1 mg/ml-100 mg/ml |
Accuracy Error | < 1 % |
Repeatability Error | < 1 % |
Semi Automatic Chemistry Analyzer F-SACA101
Measuring System | Measuring Range: 0 to 3.500 OD Method: End Point, Fixed Time, Rate etc. Photometric linearity: ±2% (0 to 2.500 OD) Photometric accuracy: ±1% (0 to 2.500 OD) |
Photometric System | Light source: 6 V, 10 W halogen lamp Filters: 304 nm, 405 nm, 450 nm, 510 nm, 546 nm, 578 nm, 630 nm and 2 open filter positions Wavelength Accuracy: ±2 nm |
Thermostatic Control | Temperature: RT, 25˚C, 30˚C, 37˚C Precision: ±0.1˚C |
Drift | <0.005 OD |
Automatic Chemistry Analyzer F-AMCA101
Throughput | 400 tests/hour |
Sample Volume | 2 to 70 µl |
Reagent Volume | 20 to 350 µl |
Sample Positions | 60/90 sample positions |
Automatic Chemistry Analyzer F-AMCA102
Throughput | 600 tests/hour |
Sample Volume | 2 to 70 µl |
Reagent Volume | 20 to 350 µl |
Sample Positions | 90 sample positions |
Automatic Chemistry Analyzer F-AMCA201
Throughput | 200 tests/hour |
Sample Volume | 2 to 70 µl |
Reagent Volume | 20 to 350 µl |
Sample Positions | 37 sample positions |
Automatic Chemistry Analyzer F-AMCA202
Throughput | 200 tests/hour |
Sample Volume | 2-70 µl |
Reagent Volume | 20-350 µl |
Sample Positions | 49 sample positions |
Automatic Chemistry Analyzer F-AMCA301
Throughput | 800 tests/hour, 1200 tests/hour with ISE |
Sample Volume | 2 to 70 µl |
Reagent Volume | 20 to 350 µl |
Sample Positions | 150 sample positions |